Introduction
Slabless, sawtooth staircase (Figure 1) is one type of the stair that produces a lot of aesthetics appeal. Aesthetics and function are prime considerations in the design of buildings so if you learn how to design and build this type of stair, it would be good to actualize it. Different codes have their way of designing this type of stair but I would dwell on the method outlined in the book by Reynolds and Steedman (1988) which is in consonance with BS 8110 and Eurocode 2 (EC 2).
According to Reynolds and Steedman (2010), Cusens (1966) showed that if axial shortening is neglected and the strain energy due to bending only is considered, the midspan moment for the sawtooth stair case can be given by the general expression.
Where k = stiffness of thread/stiffness of riser and j is the number of threads
If j is odd,
If j is even,
I refer my reader to study principles of strain energy to understand more the concept defined here.
Steps in the design of slabless stair case
Step 1; Carry out the functional design of the staircase to determine length of the span based on the stairwell and using Blondel formula to determine the suitable length of thread (going) and riser height.
The Blondel formula states thus, 2R+T = 600 mm where R = Riser and T = Thread or Going (See table 1).
Table 1; Optimum dimensions of stair case (mm) – BS 5395
Step 2; Carry out the load analysis based on EC 2 guide to determine the design load, nd. The design load is considered as concentrated load at the mid span as shown below (Figure 2)
Step 3; Determine k from the expression below, (See Figure 3 for explanation of expressions)
Where Lt = length of going/thread; Lr = length of riser; ht = height of thread; hr = height of riser
Step 4; Determine support moment coefficient from the chart in Figure 4 based on k and j
Using the support moment coefficient, calculate the support moment based on the expression below,
Support moment, Ms = coefficient x ndL2
Otherwise, follow step 4a
Step 4a; Determine the parameters, k11, k12, k13 and k14 from j, which is the number of goings/threads and determine the support moment from the expression.
Step 5; Determine the free bending moment from the expression
Step 6; Determine the maximum moment at the midspan (Mo) with the expression
Mo = M – Ms
Where M = free bending moment and Ms = support moment
Step 7; Draw the bending moment and shear force diagrams if required. They should be as shown
Step 8; Determine the reinforcement required at mid span and support based on the mid span moment and support moments and detail the slab as shown below. Due to the stair profile, concentrations of stress occur in the re-entrant corners, and the actual stresses to be resisted will be larger than those calculated from the moment. Note that re-entrant corner is any inside corner that forms an angle of 1800 or less. In a solid object subjected to internal or external loads, re-entrant corners create high stress concentrations. To resist such stresses, Cusens recommends providing twice the reinforcement theoretically required (at the re-entrant corners) unless suitable fillets or haunches are incorporated at these junctions. If this can be done, the actual steel provided should be about 10% more than the theoretically necessary. The possible reinforcement patterns are shown below (Figure 7)
Figure 7 is very suitable but practically, if haunches are provided otherwise the bars should be arranged for wall-to-wall corners as shown below (Figure 8).
If Figure 7 would not be possible, Figure 9 can be adopted for the reinforcement
Example
A proposed slabless stair case has the following geometrical details and design information
Length of going/thread, Lt= 300 mm
Length of Riser, Lr = 150 mm
Height of thread, ht = 125 mm
Height of riser, hr = 125 mm
Number of threads = 6
Width of stair = 1200 mm
Length of stair, L = 300 x 6 = 1800 mm
Variable action (public access) = 3.0 kN/m2
Weight due to finishes as 1.5 kN/m2
Unit weight of concrete = 25 kN/m3
Characteristic strength of concrete, fck = 25 N/mm2;
Characteristic strength of steel, fyk = 460 N/mm2
Determine the support moments and midspan moment and design the stair
Step 1; The functional design parameters are outlined above
Step 2; Loading
Self-weight of the staircase = {[(Lt x ht) + (Lr x hr)]/Lt} x fck = {[(0.3 x 0.125) + (0.15 x 0.125)]/0.3 x 25 =
0.1875 x 25 = 4.69 kN/m2
Weight of finishes = 1 kN/m2
Total permanent action = 4.69 + 1 = 5.69 kN/m2
Variable action = 3 kN/m2
Design action, nd = 1.35gk + 1.5qk = 1.35 (5.69) + 1.5 (3) = 12.18 kN/mper m width, say 13 kN/mper m width
Step 3; Determination of k
K = (ht3lr)/ (hr3lt) = (1253 x 150) (1253 x 300) = 150/300 = 0.5
Step 4; Determine support moment coefficient from the chart in Figure 4 based on k and j
Since k = 0.5 and j = 6 the support moment coefficient from chart = -0.875
Support moment, Ms = -0.0875 x 13 x 1.82 = -3.69 kNm
Using formula to estimate this value, since j is even,
= ((1/48) x 6 x (6-1) x (6-2) = 2.5
= (1/48) x (6-1) x (6-2) x (6-3) = 1.25
= (1/2) x (6-1) = 2.5
= (1/2) x (6-2) = 2
Ms = [13 x 1.82 (2.5 + (0.5 x 1.25))]/62[2.5 + (0.5 x 2)] = 131.625/126 = 1.044 kNm (the value is lower than one obtained from chart). We would proceed with the value from chart.
Step 5; Determine the free bending moment. Since j is even, free bending moment, M = (1/8) x 13 x 1.82 = 5.265 kNm
Step 6; Determine the maximum moment at the midspan (Mo) with the expression
Mo = 5.265 – 3.69 = 1.575 kNm
Step 7; Draw the bending moment and shear force diagrams if required. They should be as shown
Step 8: Estimation of area of reinforcement: In slabless stair case, the links are designed while the main bars are provided. It is usually 6 number of bars per link and of the same size as the link.
MEd = 1.575 kNm
b = 1000; fck = 25 N/mm2
Assuming bar size of 12 mm and concrete cover of 25 mm, d = 150 – 25 – (12/2) = 119 mm
k = 1.575 / (25 x 1000 x 1192) = 0.00445 < 0.167 Ok
z = d (0.5 + √0.25 – 0.882k) = 0.99d ˃ 0.95d, use 0.95d
z = 0.95 x 119 = 133 mm
As1 = 1.575/ (0.87 x 460 x 113) = 34.83 mm2/m provide H12@ 300 mm c/c (377 mm2/m)
Check for shear
Maximum design shear force, MEd = 11.7 kN/m
k = 1 + √ (200/d) = 1 + √ (200/119) = 2.30 ˃2.0, use 2.0
ρl = As1/bd = 34.83/(1000 x 119) = 0.000293 ≤ 0.02
VRd,c = [0.12k(100ρlfck)1/3] bd = [0.12 x 2 (100 x 0.000293 x 25)1/3 x 1000 x 119 = 25.75 kN/m
Since VEd (11.7 kN/m) ˂ VRd,c (25.75 kN/m), shear is satisfied
Reinforcement details
References
Cusens, A. R. (1966): Analysis of slabless stairs. Concrete and Constructional Engineering 61(10), pp. 359—64.
Reynolds, C.E. and Steedman, J.C. (1988): Reinforced Concrete Designer’s Handbook, 10th edition. E & FN Spon, Taylor & Francis Group 11 New Fetter Lane, London.
4 Comments
This is really interesting, You are a very skilled blogger.
I have joined your feed and look forward to seeking more of your excellent
post. Also, I have shared your website in my social networks!
Hello my loved one! I want to say that this post is awesome, great written and include approximately all vital infos.
I would like to look extra posts like this .
Genuinely when someone doesn’t understand then its up
to other users that they will assist, so here it happens.
Somebody necessarily lend a hand to make significantly posts I’d state.
This is the first time I frequented your website page and to this point?
I amazed with the research you made to make this actual publish amazing.
Great job!